Search found 12 matches

by BitterCondition
Sat Feb 24, 2018 11:50 pm
Forum: System support
Topic: Payout for ETC 2-2418 not received - Please Check
Replies: 1
Views: 1416

Re: Payout for ETC 2-2418 not received - Please Check

Steve and Chris ... payout finally made into the wallet at 9:49pm EST... thank-you.... BitterCondition
by BitterCondition
Sat Feb 24, 2018 5:00 pm
Forum: System support
Topic: Payout for ETC 2-2418 not received - Please Check
Replies: 1
Views: 1416

Payout for ETC 2-2418 not received - Please Check

Steve & Chris... main screen shows a payout for ETC to my ETC wallet, however, payment has never arrived into the wallet for 2-24-18... last received was yesterday 2-23-18 payout... could you please check your end... here is the transaction ID from the main screen Payout EthereumClassic -0.27462...
by BitterCondition
Tue Sep 19, 2017 4:27 pm
Forum: System support
Topic: Auroracoin Payments
Replies: 4
Views: 3057

Re: Auroracoin Payments

Thanks guys for getting to this it was very much appreciated......
by BitterCondition
Tue Sep 19, 2017 9:59 am
Forum: System support
Topic: Auroracoin Payments
Replies: 4
Views: 3057

Re: Auroracoin Payments

bump
by BitterCondition
Mon Sep 18, 2017 11:16 am
Forum: System support
Topic: Auroracoin Payments
Replies: 4
Views: 3057

Re: Auroracoin Payments

You are not the only one... I have 2 auraura coin payments not paid out threshhold met on both days for this coin... 9/14 and 9/15.... I knew they were having troubles and gonna do server maintenance so I waited until yesterday to file a ticket...Steve and Chris please check into this...I have been ...
by BitterCondition
Fri Aug 11, 2017 7:57 pm
Forum: System support
Topic: Advice on Fan settings for Temp control
Replies: 6
Views: 7444

Re: Advice on Fan settings for Temp control

Given the history of hashcard failures across S7, S9, R1 and L3 Bitmain miners, I wouldn't be relying on that thermal protection failsafe myself. You have to remember that's there's likely to be a single temp sensor per card, leaving lots of room for a localized heat spike above 80°C which damages ...
by BitterCondition
Thu Aug 10, 2017 10:56 pm
Forum: System support
Topic: Advice on Fan settings for Temp control
Replies: 6
Views: 7444

Re: Advice on Fan settings for Temp control

What miner is that? For L3+ if temps are below 78°C/172°F its fine... in fact below 80°C its ok It is an L3+.... I only have one......... so it would be alright then to reset back to factory default which was blank .... there is a checkbox for automatic shutdown at 80 degrees which is factory check...
by BitterCondition
Thu Aug 10, 2017 9:58 pm
Forum: System support
Topic: Advice on Fan settings for Temp control
Replies: 6
Views: 7444

Re: Advice on Fan settings for Temp control

Ty info.... I set the custom percentage on the miner to 72%.....it got a heck of a lot louder but overall lowered the temp settings on the PCD's and Chips by 4 degrees on each one...should I go higher than 72% and will it burn out the fans running that hard? Edit forgot to mention that this raised t...
by BitterCondition
Thu Aug 10, 2017 6:40 pm
Forum: System support
Topic: Advice on Fan settings for Temp control
Replies: 6
Views: 7444

Advice on Fan settings for Temp control

Would these Highlighted readings be normal or should I manually set fan speed higher to lower temp Chain# ASIC# Frequency MH/S(RT) HW Temp(PCB) Temp(Chip) ASIC status 1 72 384 120.95 0 I:0 O:49 Temp PCB I:0 O:57 Temp Chip oooooooo oooooooo oooooooo oooooooo oooooooo oooooooo oooooooo oooooooo oooooo...
by BitterCondition
Wed Aug 09, 2017 12:13 am
Forum: News
Topic: Issues to be investigated soon
Replies: 17
Views: 9997

Re: Issues to be investigated soon

platoday wrote:earned 50% less compared to yesterday.

I did rough calc and I am between 38% to 42% lower... and the live balance counter while working is not resetting after the cutoff for next day balance stats